Back to top

Safevolt Electrical Insulating Mats

Safevolt Electrical Insulating Mats
Safevolt Electrical Insulating Mats

Safevolt Electrical Insulating Mats Specification

  • Installation Guideline
  • Lay flat over floor area, cut as per requirement, no adhesive required
  • Size
  • Standard Roll: 10 meters; Custom sizes available
  • Feature
  • Flame Retardant, Non-conductive, Resistant to Acids, Alkalis, Oils, and Fire
  • Density
  • 1.5 Gram per cubic centimeter(g/cm3)
  • Thermal Conductivity
  • Low, suitable for electrical insulation
  • Coating Type
  • No additional external coating
  • Layer
  • Single layer, solid construction
  • Surface Treatment
  • Anti-skid, both sides textured or one side plain
  • Product Type
  • Electrical Insulating Mats
  • Material
  • Rubber
  • Rated Voltage
  • 3.3 kV, 11 kV, 33 kV
  • Tensile Strength
  • Minimum 15 N/mm2
  • Width
  • 2-3 Millimeter (mm)
  • Thickness
  • 2 mm, 2.5 mm, 3 mm, 3.5 mm, 4 mm, 5 mm, 6 mm, 8 mm, 10 mm
  • Application
  • Insulation
  • Breakdown Voltage
  • Greater than 40 kV
  • Heat Conductivity
  • Low
  • Color
  • As Per Requirement
  • Max Withstanding Temperature
  • -10C to +55C
  • Dielectric Strength
  • 40 kV for 1 minute as per IS:15652
  • Ozone Resistance
  • Excellent
  • UV Resistance
  • Yes
  • Water Absorption
  • Less than 0.5%
  • Shelf Life
  • 5 Years from date of manufacture
  • Elongation at Break
  • 250% Minimum
  • Weight per Square Meter
  • Varies with thickness, approx. 3-9 kg/m2
  • Insulation Resistance
  • Greater than 1,00,000 Mega Ohms
  • Surface Finish
  • Textured / Anti-slip
  • Flame Resistance
  • Self-extinguishing
 

Safevolt Electrical Insulating Mats Trade Information

  • Minimum Order Quantity
  • 590 Square Meters
  • FOB Port
  • Kolkata
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 5000 Square Meters Per Month
  • Delivery Time
  • 3 Week
  • Sample Available
  • No
  • Sample Policy
  • Within a certain price range free samples are available
  • Packaging Details
  • HDPE Packaging
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • BIS, RoHs
 

About Safevolt Electrical Insulating Mats

The Duratuf electrical insulating mats are highly favored for their functionality and durability. We offer a wide range of insulating rubber mats under 1 roof. The X-Volt electrical rubber mats comply with the IS 15652 safety standard.

As a trusted electrical rubber mat supplier, we provide third-party type-tested certificates with our X-Volt electrical mats. Furthermore, their upper surface has prominent ISI markings on every meter (following the latest IS 15652:2006 safety standard).

Our electrical floor mats are considered vital safety equipment. Whether it is a production unit or a commercial set-up, the Duratuf X-Volt insulation rubber mats reduce electrical hazards. Besides electrical insulation, they offer lower leg comfort to the workers standing on them for hours.

The insulating mats are anti-slip having a dotted surface. You can choose between the blue and black colors of the X-Volt insulated rubber mats.



Unmatched Electrical Protection

Engineered to provide insulation resistance exceeding 1,00,000 Mega Ohms and a dielectric strength of 40 kV, Safevolt mats effectively prevent accidental electrical shocks. These mats are key to ensuring workplace safety during electrical operations in diverse environments such as substations, factories, and industrial floors.


Flexible, Durable, and Long-Lasting

With an elongation at break of 250% minimum and tensile strength above 15 N/mm2, Safevolt mats combine flexibility with robustness. Their single-layer, solid rubber construction resists acids, alkalis, oils, fire, UV rays, and ozone, ensuring longevity and optimal performance for up to five years from manufacture.


Simple and Versatile Installation

No special adhesives or tools are needed: simply lay the mats flat over the desired floor area and cut them to fit, leveraging the anti-slip textured finish for extra safety. Standard 10-meter rolls and custom sizes address unique installation requirements in all facility types.

FAQ's of Safevolt Electrical Insulating Mats:


Q: How do I install Safevolt Electrical Insulating Mats?

A: Installation is straightforward: Lay the mat flat across the required floor area and cut to fit as necessary. The mats require no adhesives and are ready for use immediately after placement, thanks to their textured, anti-skid surfaces.

Q: What benefits does using Safevolt Electrical Insulating Mats provide?

A: These mats ensure high levels of electrical safety by providing insulation resistance over 1,00,000 Mega Ohms and dielectric strength of 40 kV. They are flame-retardant, self-extinguishing, and resist chemicals, making them suitable for use in harsh industrial and electrical environments.

Q: Where can Safevolt mats be used effectively?

A: Safevolt mats are ideal for use in electrical substations, switch rooms, workshops, high-voltage installation areas, and control panels. Their robust, anti-slip design and resistance to industrial hazards make them versatile for a range of professional settings.

Q: What is the minimum and maximum thickness available for these mats?

A: Safevolt Electrical Insulating Mats are available in thicknesses ranging from 2 mm to 10 mm, allowing selection as per voltage rating and insulation requirements.

Q: When should the mats be replaced?

A: Safevolt mats have a shelf life of five years from the date of manufacture. Inspection should be done periodically, and replacement is recommended if the mat sustains visible damage or exceeds the shelf life.

Q: What processes ensure the mats' resistance to flame, UV, and chemicals?

A: The mats are manufactured from special compounds in a single solid rubber layer, providing self-extinguishing flame resistance, as well as excellent ozone, UV, and chemical resistance without the need for external coatings.

Q: How are Safevolt mats beneficial in preventing accidents?

A: The mats' high insulation values, anti-skid surface, and robust material help prevent electrical shocks and slips, thereby ensuring overall safety for personnel working near electrical equipment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Insulating Mats Category

High Voltage Electrical Insulation Rubber Mat Class B for 11 KV

High Voltage Electrical Insulation Rubber Mat Class B for 11 KV

Price 675.0 INR / Piece

Minimum Order Quantity : 10 Kilograms

Material : Rubber

Color : Black

Application : Electrical Safety in HT & LT Panels

Product Type : Insulating Mat

Electrical Insulating Rubber Mat for Panels Shock-Proof and Durable

Electrical Insulating Rubber Mat for Panels Shock-Proof and Durable

Price 540.0 INR / Pack

Minimum Order Quantity : 10 Packs

Material : Rubber

Color : Black

Application : Electrical insulation, PCB substrate

Product Type : Insulating Mat

Durable Insulating Mats for Electrical Work X-Volt Premium Quality

Durable Insulating Mats for Electrical Work X-Volt Premium Quality

Price 540.0 INR / Meter

Minimum Order Quantity : 300 Square Meters

Material : Rubber

Color : Black

Product Type : Insulating Mat

High Voltage Electrical Insulation Rubber Mat Class B for 11 KV

High Voltage Electrical Insulation Rubber Mat Class B for 11 KV

Price 675.0 INR / Meter

Minimum Order Quantity : 300 Pieces

Material : Rubber

Color : Black

Application : Electrical insulation, PCB substrate